General pitting of the external tube surface should be
evaluated with a pit depth gauge to assess the depth and to estimate a pitting
rate. The gauge should be used in conjunction with an ultrasonic thickness
gauge to more accurately determine remaining wall thickness. Scale on the tubes
will mask pits and so it is prudent to remove scale in selected areas to find
the deterioration.