PIT DEPTH MEASUREMENTS

General pitting of the external tube surface should be evaluated with a pit depth gauge to assess the depth and to estimate a pitting rate. The gauge should be used in conjunction with an ultrasonic thickness gauge to more accurately determine remaining wall thickness. Scale on the tubes will mask pits and so it is prudent to remove scale in selected areas to find the deterioration.