Standards, Codes, and Specifications commonly used for Boilers/ Heater / Furnaces



API
Std. 530    Calculation of Heater Tube Thickness in Petroleum Refineries
RP 534      Heat Recovery Steam Generators
RP 535      Burners for Fired Heaters in General Refinery Services
RP 556      Fired Heaters and Steam Generators
Std. 560    Fired Heaters for General Refinery Services
RP 571      Damage Mechanisms Affecting Equipment in the Refining Industry
RP 572      Inspection of Pressure Vessels, Heat Exchangers, Condensers, and Coolers
RP 576      Inspection of Pressure Relieving Devices
RP 578      Material Verification Program for New and Existing Alloy Piping Systems
RP 579      Fitness-For-Service
RP 580      Risk Based Inspection

AISC
M015L      Manual of Steel Construction, Load and Resistance Factor Design
M016         Manual of Steel Construction, Allowable Stress Design

ASME
B16.9        Factory-Made Wrought Steel Buttwelding Fittings
B16.28      Wrought Steel Buttwelding Short Radius Elbows and Returns
B31.1        Power Piping
B31.2        Fuel Gas Piping
B31.3        Chemical Plant and Petroleum Refinery Piping
B31.4        Liquid Transportation Systems for Hydrocarbons, Liquid Petroleum Gas, Anhydrous Ammonia, and Alcohols
B31.5        Refrigeration Piping
B31.8        Gas Transmission and Distribution Piping Systems
B31.9        Building Services Piping
B31.11      Slurry Transportation Piping Systems
B31           Guide        Corrosion Control for ANSI3 B31.1 Power Piping Systems
B31G        Manual for Determining the Remaining Strength of Corroded Pipelines: A Supplement to B31, Code for Pressure Piping

ASME Boiler and Pressure Vessel Code
Section I    Power Boilers
Section IV Heating Boilers
Section VI Recommended Rules for Care and Operation of Heating Boilers
Section VII     Recommended Guidelines for Care of Power Boilers

NB
NB-23       National Board Inspection Code

ASTM
A 297        Steel Castings, Iron-Chromium and Iron-Chromium-Nickel, Heat-Resistant, for General Application

NACE
RP0170     Protection of Austenitic Stainless Steel From Polythionic Acid Stress Corrosion Cracking During Shutdown of Refinery Equipment

Sailent features of Pollution Control Board


1. CFE is valid for 5 years (KSPCB)
2. The industry shall use only Low Nox Burners
3. Online stack analyzers shall be installed along with online VOC Analyzers
4. Portholes shall be provided for all chimneys, stacks and other sources of emission. These shall serve as sampling points. The diameter of the sampling port should not be less than 3".The parthole shall be closed firmly when not used for sampling. An easily accessible platform to accomodate 3 to 4 persons to conveniently monitor the stack emission from the portholes shall be provided
5. Form -XIII : Application for consent for establishment or taling any step for establishment of industries, operation, or any process or any treatment disposal system or discharge, continuation of discharge under section 25/26 of the water (prevention & control of pollution) Act, 1974
6. Form -I : Application for consent for discharge of emission/continuation of discharge of emission under sectio0n 21 of the air(prevention and control of pollution) Act, 1981

Specific Conditions to obtain environmental clearance for any industry


No objection certificate from SPCB
Coastal Regulation Zone Notification 1991
A report from Wildlife Department marine Impact assessment and risk assessment along with the Disaster Management Plan shall be prepared
Ambient air quality along with SO2 Nox and other parameters shall put up in a dedicated website to the public
Emission levels of pollutants shall be within permissive levels
33% of the area shall be dedicated green belt development (Local Forest Department)
The traffic in the city shall not get affected
Water supply to the nearby places shall not get affected
Detailed monitoring program  shall be designed and information shall be provided to the public in a dedicated website by online monitoring
Low sulfur internal fuel and fuel gas shall be fired in process heaters and boilers
Quarterly monitoring of fugitive emissions shall be carried out by Fugitive Emission Detectors
Regular Ambient air quality monitoring  - SPCB
Online data for air emissions shall be transferred to the CPCB and SPCB regularly
The practice of acoustic plant design shall be adopted to limit noise exposure for personnel to an 8 hr time weighted average of 90 dB
Adopt Leak Detection and Repair program for quantification and control of fugitive emissions
No halogenated organic is sent to flare
Regular monitoring of underground water parameters shall be carried out in nearby areas
Solid waste generated shall be disposed of as per SPCB
Oil shall be recovered firm oily sludge and oil to be reused and sludge will be stored in HDPE lined pit 
Follow recommendations mentioned in the charter on CERP (Corporate Responsibility for Environmental Protection
Rainwater harvesting, storm water drains to recharge the ground water  - conserve fresh water
Occupational Health surveillance of the workers should be done on regular basis - Factories Act
Environmental Impact Assessment/EMP Report and Risk Assessment Report 
Expansion and modification shall be made after prior approval

Mahindra Renault - Specifications

Prevention : To develop the responsibility of the driver with information systems.

Correction : To provide equipments that compensate for driving errors.

Protection : To provide advanced protective systems that minimize the risk of injury if an accident does happen.

Acoustics: Renault’s soundproofing work covers all interior and exterior noise sources. Outside noise level is lower than that stipulated by European standards.

Visibility and Space: Sunroofs are being extended across the Renault range.

Ergonomics: Automatic systems reduce the risk of driver distraction by taking charge of certain routine operations such as switching on the headlights. The advanced design runs hand in hand with technological innovation to produce controls that are intuitive to operate and pleasant to the touch.

Front Wheel Allignment :General Technical Specifications

FRONT WHEEL ALIGNMENT AT KERB WEIGHT
Wheel Alignment Angles -
Camber
Caster
Toe-in Degrees Total & Degrees per Wheel
Toe-out on Turns
Steering Axis Inclination Angle
Included Angle

FRONT SPRING SPECIFICATIONS
Model
Approximate number of coils
Approximate free length
Inside Diameter
Spring Type & Rating

General Technical Specifications for Bicycles - Boys & Girls

  • Standard : IS 10613-1983 with Hand Operated Lever Brake System.
  • Frame As per IS 623-1963 
  • Dimension of Seat Tube IS-3404-1966
  •       a) Outside diameter of seat tube 28.6 mm
  •       b) Thickness of Seat Tube 1.63 mm
  • Saddle : PVC Saddle with rexine cover. 
  • Lock
  • Gear Bell (Minimum size of the Gear Bell cup) 
  • Colour
  • Stand
  • Carrier 
  • Gear Case
  • Basket
  • Tyre & Rim (vary with boys and girls cycles)
  • Thickness of Rim : As per IS 624
  • Size (vary with boys and girls cycles)
  • Pedals
  • Rim Tape
  • Air Filling
  • Warranty
  • Sari Guard ( only for Girls Cycles)